Parameter Description and Range US Upper set point -9.9 to 9.9 C diF Differential 0.1 to 9.9 C CA Calibration +/-9.9 C Ct Not applicable N/A FAC Factor 0 to 255 Ht Max allowable high temperature 55 - 110 C Tr Min fridge run time 0 to 240 secs LGL Lower Gradient Limit -9.9 to 9.9 UGL Upper Gradient Limit -9.9 to 9.9 To change the parameter values, switch the power to the unit off, push the temperature set button and keep it pushed whilst switching the power to the unit back on again. The display will flash and intermittently show the figures 888. Once the display stops flashing, the instrument is in parameter mode. To scroll through the parameters push the set point button and to change the values of the parameters use the ‘adjust’ buttons. When finished, release all buttons and wait until the display shows the actual temperature again. Important If the power to the unit is switched off whilst the instrument is still in parameter mode, the system will NOT accept the changes. The only parameter that should need to be altered from the factory settings is US. The factory setting is —1.5 which delivers product into the glass at approximately 2.0°C. If this setting needs to be altered, it will change in steps of 0.1°C. ERROR CODES
If in doubt switch unit off and back on again and if fault persists call +44(0) 1226 246 999. |
|
|